KUSTERS WATER DIVISION

Headworks  |  Thickening  |  Clarification  |  Biosolids  |  Odor Control  |  Biological

GRIT WASHER

The Kusters Water ProTechtor® Grit Washer is known for its reliable operation and robust design. Separation efficiencies of the grit washer are much higher than conventional grit classifiers. All ProTechtor® products are US Manufactured at Kusters Water’s ISO 9001:2015 certified facility.

PRINCIPLE OF OPERATION

The grit slurry is fed into the grit washer through the inlet. Organics material is held in suspension, captured then released via the organics reject valve. Heavier grit particles settle in the washer tank for further cleaning. With the addition of water, a stirring device and up-current wash water technique the settled grit is separated from the remaining organics constituents. The washed grit is then removed with an extraction screw, dewatered and discharged. Typical grit contains less than 3% organics and is 90% dry.

TYPICAL SEQUENCE OF OPERATION

XGT GRIT TRAP AND VORTEX GRIT WASHER

AUTOMATIC OPERATION:

table-1

INITIAL CONDITIONS FOR AUTOMATIC OPERATION

Control Power OFF/ON

ON

Grit Pump Hand-Off-Auto

In AUTO

Scour Valve Open-Close-Auto

In AUTO

XGT Impeller Drive OFF/ON

ON Position

Grit Washer Agitator Hand-Off-Auto

In AUTO

Grit Washer Auger Hand-Off-Auto

In AUTO

Grit Washer Grit Bed Wash Valve Open-Close-Auto

In AUTO

Grit Washer Organics Drain Valve Open-Close-Auto

In AUTO

Emergency Stops:

Not Activated

MANUAL OPERATION of the Grit System:

table-2

INITIAL CONDITIONS FOR MANUAL CONTROL

Emergency Stops:

Not Activated

FAULT CONDITIONS

AUXILIARY CONTACTS

MAIN CONTROL PANEL

LIST OF ADJUSTABLE TIMERS & SETPOINTS

table-3

DESCRIPTION

INITIAL SETTING

RANGE

Time Clock Low Flow

60 minutes

15 – 720 minutes

Time Clock High Flow

30 minutes

15 – 360 minutes

Scour Valve Duration Timer

1 minute

0 – 10 minutes

Grit Pump Cycle Timer

10 minutes

0 – 30 minutes

Grit Washer Agitator/Wash Water Valve Off Delay

5 minutes

0 – 15 minutes

Grit Washer Organics Drain Valve Open Time

15 seconds

0 – 60 seconds

Grit Washer Organics Drain Valve Closed Time

90 seconds

0 – 120 seconds

Grit Washer Auger Cycle On Delay

30 seconds

0 – 60 seconds

Grit Washer Auger Cycle Off Delay

2 minutes

0 – 5 minutes

Grit Washer Auger On Time

30 seconds

0 – 60 seconds

Grit Washer Auger Off Time

30 seconds

0 – 60 seconds

Grit Bed Level Sensor – ‘Grit Pump ON’

Set at Start-Up

0 – 200 mbar

Grit bed Level Sensor – ‘Grit Pump OFF’

Set at Start-Up

0 – 200 mbar

NOTE: These are initial settings and may need adjustment for actual site conditions. All timers and settings are adjustable in the PLC.